Journal Watch: Loxoprofen overdose without toxicity: analysis of loxoprofen pharmacokinetics through use of LC–MS

LC-MS

Journal Watch: Loxoprofen overdose without toxicity: analysis of loxoprofen pharmacokinetics through use of LC–MS

17 Jun, 2026


Open Access:
International Journal of Emergency Medicine


ABSTRACT

Background

Loxoprofen, widely used as a nonsteroidal anti-inflammatory drug worldwide, is a prodrug that is converted to its active trans-hydroxylated metabolite. Reports of loxoprofen overdose are extremely limited, and asymptomatic cases despite massive ingestion have not been previously documented.

Case presentation

A 43-year-old woman ingested 8,280 mg of loxoprofen. She arrived at the hospital two hours later in a clinically stable condition. Laboratory tests and electrocardiography were unremarkable, and abdominal computed tomography revealed no gastric contents. She remained asymptomatic, with normal laboratory findings throughout the hospitalisation period, and was discharged on day 3. Pharmacokinetic analysis using liquid chromatography–mass spectrometry revealed markedly elevated plasma concentrations of loxoprofen and its metabolites two hours after ingestion (loxoprofen 159 µg/mL, trans-OH 64 µg/mL, cis-OH 29 µg/mL), which declined rapidly thereafter.

Conclusion

This case suggests that markedly elevated plasma concentrations of loxoprofen and its metabolites do not necessarily result in toxicity. Pharmacokinetic findings indicate that rapid metabolism may prevent organ damage.


For further reading please visit: 10.1186/s12245-026-01256-4


http://creativecommons.org/licenses/by-nc-nd/4.0/

Latest News

Explore Our Other Sites

Labmate Online
Fungal and bacterial triggers may be drivers in steroid-resistant asthma
Explore more Arrow
Envirotech Online
New oxygen sensor range targets OEM gas detection applications
Explore more Arrow
Pollution Solutions Online
Skid-mounted systems target oxygen and moisture removal for renewable natural gas
Explore more Arrow
Petro Online
Automated freezing-point testing arrives for jet fuel: what ASTM D8615 changes for lab workflows
Explore more Arrow