Targeted Analysis and Accurate Profiling of Volatiles and Semi-volatiles in High Complexity Samples
Targeted Analysis and Accurate Profiling of Volatiles and Semi-volatiles in High Complexity Samples
Targeted Analysis and Accurate Profiling of Volatiles and Semi-volatiles in High Complexity Samples
Targeted Analysis and Accurate Profiling of Volatiles and Semi-volatiles in High Complexity Samples

Gas chromatography

Targeted Analysis and Accurate Profiling of Volatiles and Semi-volatiles in High Complexity Samples

14 Aug, 2017

Published over 9 years ago. See the latest and most current information on Gas chromatography.

GC×GC-HRMS is one of the most powerful tools available to analytical chemists for the targeted analysis and accurate profiling of volatiles and semi-volatiles in samples of high complexity. This technique combines the excellent resolving power granted by two-dimensional separations with accurate mass measurements that provide a substantial advantage for identity confirmation. It is therefore not surprising that GC×GC-HRMS is increasingly more accepted in labs dealing with challenging analytical requests in very complex matrices such as, for instance, environmental and food analysis.

JSB recently investigated the use of GC×GC with Zoex thermal modulation coupled to an Agilent QTOF detector for quantification of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs). These compounds are synthetic chlorinated compounds banned or restricted due to their toxicity to humans and impact on the environment but, being persistent pollutants, are still present as residues in soil, water, food etc. Their identification and quantification is of great importance for environmental and food safety since they represent a risk even at very low level. The QTOF grants wide operational flexibility allowing EI and CI acquisition, as well as MS/MS capability. In this example JSB selected the NCI to obtain higher sensitivity for the halogenated compounds. The results obtained for linearity and repeatability show that GC×GC with thermal modulation and QTOF are robust and provide performance suitable for reliable identification and quantification at low concentrations.

Latest News

Explore Our Other Sites

Labmate Online
Single medium supports both 2D and 3D pluripotent stem cell culture and growth
Explore more Arrow
Envirotech Online
Meeting to explore the challenges of measuring ammonia across energy, healthcare and the environment
Explore more Arrow
Pollution Solutions Online
Vacuum technology enables efficient lithium-ion battery recycling with recovery rates of up to 95%
Explore more Arrow
Petro Online
The expanding role of high-temperature, high-shear viscometry in modern engine oil development
Explore more Arrow