• New Method for Low Level Detection of Volatile Nitrosamines in Tobacco   

GC, MDGC

New Method for Low Level Detection of Volatile Nitrosamines in Tobacco  

Thermo Fisher Scientific announce a new comprehensive method that uses triple quadrupole GC-MS/MS to achieve lower levels of detection of volatile nitrosamines (VNA) in tobacco. The new method allows environmental laboratories, tobacco companies and government agencies to efficiently separate VNAs while lowering detection limits, increasing specificity and enabling the analysis of many other contaminants in tobacco, including pesticides. The new method is detailed in an application note entitled “Lower Detection Limits of Volatile Nitrosamines in Tobacco by Triple Quadrupole GC-MS/MS,” available to download at www.thermoscientific.com/vna.

Volatile nitrosamines are a class of compounds that can form in tobacco smoke, as well as during the curing and processing of tobacco. These compounds have been proven to have adverse effects on human health; and two of the VNAs found in tobacco, N-nitrosodiethylamine (NDEA) and N-nitrosodimethylamine (NDMA), are classed as known human carcinogens by regulatory authorities. As a result, these compounds must be thoroughly monitored in order to safeguard human health and comply with increasingly stringent regulations.

The new Thermo Fisher method is a powerful alternative to other traditionally used techniques. By coupling a gas chromatograph to a triple quadrupole mass spectrometer, the new method makes detection limits of 1ng/mL achievable, enabling users to satisfy the increasingly lower detection limits required by governments and regulatory bodies. The method also increases contaminant specificity within a classification and allows many other organic contaminants and chemicals in tobacco to be analyzed simultaneously, including pesticides.

The new method includes GC-MS/MS analysis on the Thermo Scientific TSQ Quantum XLS triple quadrupole GC-MS/MS system using timed selected reaction monitoring (t-SRM). This unique feature enables easy method set-up and allows users to run samples while the instrument automatically determines the optimal time for SRM parameters.

For more information visit www.thermoscientific.com/gc.
 


Events

LabAsia 2025

Jul 14 2025 Kuala Lumpur, Malaylsia

SinS Solutions in Science

Jul 15 2025 Brighton, UK

ACS National Meeting - Fall 2025

Aug 17 2025 Washington DC, USA & Virtual

MC 2025

Aug 31 2025 Karlsruhe, Germany

CE Pharm 2025

Sep 07 2025 Rockville, MD

View all events