  • New Cylinder-free Auto-GC-FID Range

New Cylinder-free Auto-GC-FID Range

Nov 11 2019 Read 2651 Times

Reliable and certified results from an all-in-one unit without gas cylinders: this was the design challenge that Chromatotec achieved to satisfy market expectations for VOCs/Hydrocarbons monitoring.

Gas Chromatography (GC) analysers with Flame Ionisation Detection (FID) allow the speciation of Volatile Organic Compounds (VOCs) with exceptional sensitivity and linear response for wide concentration ranges (ppt to %) in automatic routine mode. When comparing lab GC-FID with auto-GC-FID used in the field for online monitoring systems, users may be concerned with the on-site use of hydrogen (H2) and the complexity of cylinder management. Indeed, FID detectors require a H2/air flame and, in the case of cylinders, must be changed before exhaustion, or else risk interrupting analyses while also decreasing the usable amount of gas. In terms of safety, gas cylinders are bulky and heavy so personnel must be trained on how to move and secure them.

To solve these problems, H2 and zero air gas generators are used, instead of cylinders, in the first fully- automatic, standalone, cylinder-free, auto-GC-FID system manufactured by Chromatotec.

Designed for industrial applications, the performance of the cylinder-free auto-GC-FID system is highlighted by its many valuable features. The system offers low ownership cost as only distilled water and ambient air are needed. The integrated generators provide the FIDs total gas consumption requirement. (30 mL/min H2 and 180 mL/min air).

No compressed hydrogen cylinders are required guaranteeing improved safety. The FID can be operated continuously, avoiding the exchange of empty cylinders. ‘Zero grade’ gases without hydrocarbon impurities allows for lower noise level and greater column protection resulting in for greater sensitivity. The system saves space as the analyser and both generators are housed in an all-in-one wall-mounted cabinet.

Multi-streammethod analysis (channelled/surface/ambient) is achieved with a custom-designed analyser and integrated multiplexer sampling device to provide inlet/outlet process monitoring with full traceability for each streammethod type analysed.

The measurement system performance evaluation is completed with internal calibration using NIST traceable permeation tube technology to provide automatic data validation. This fully automatic, user-friendly system does not require specialised personnel to operate. You’ll only need to ensure proper power supply and to set up proper sampling lines to operate.

More information online: www.chromatotec.com

Reader comments

Do you like or dislike what you have read? Why not post a comment to tell others / the manufacturer and our Editor what you think. To leave comments please complete the form below. Providing the content is approved, your comment will be on screen in less than 24 hours. Leaving comments on product information and articles can assist with future editorial and article content. Post questions, thoughts or simply whether you like the content.

Post a Comment





Digital Edition

Chromatography Today - June 2020

June 2020

In This Edition Articles Fundamental Aspects - Separation of the 4 Enantiomers of the Fungicide Spiroxamine by LC-MS/MS - Optimising the Chiral Separation of the Pesticide Diniconazole...

View all digital editions

Events

BMSS Annual Meeting - CANCELLED

Sep 08 2020 Sheffield, UK

Mass Spec 2020

Sep 14 2020 Virtual Symposium

ISC 2020 - POSTPONED TO 2022#

Sep 21 2020 Budapest, Hungary

MSB 2020 - NEW DATES

Sep 27 2020 Saint-Malo, France

CE Pharm 2020 - ONLINE EVENT

Sep 28 2020 Bethesda, MD, USA

View all events