In HPLC often slitted or cross-slitted Silicone/PTFE Septa are used, in order to offer a penetration aid for the fairly thick and dull needles used in the HPLC instruments. While the instrument needle requires the slitted septa, the user may run into the risk of concentration changes due to the evaporation of solvents. The risk increases with the volatility of the solvent used and especially in cases of e.g. Hexane this problem may end in
none-reproduceability of analysis results. Furthermore there is a risk that the volatile solvent may extract something out of the carrier material of the septa (i.e. mainly out of the Silicone), as the chemically inert PTFE-lamination has been cut through as well as the Silicone layer with slitted or cross-slitted liners. Thus two risks (concentration change + contamination through extraction) with a lot of impact to the analysis go along with slitted septa, even though the needle may require it.

In order to avoid these risks, La-Pha-Pack has developped the so-called pre-cut septa. Here the Silicone carrier material is cut through in Y-form, however, the PTFElamination remains unhurt. As the Silicone part of the septa represents 95 per cent of the complete septa thickness, the needle can easily penetrate through the Y-slit for most of the septa’s thickness. Only the 0.05mm thick PTFElamination which is uncut, needs to be penetrated by the HPLC needle itself, but this goes without any problems even for these needles. The intact PTFE-lamination will also give 100 per cent protection to the sample with regard to any possible contamination until the needle pierces through it to pull out the sample for injection. The Y-form of the pre-cut was choosen, in order to give the needle a lot of target area for penetration, even if the needle doesn’t come down centrically. Besides that the Y-form of the pre-cut allows a better flow of air during sample pick up, in order to avoid a vacuum in the vial.

Samples can be requested at service@la-pha-pack.com at any time.


Digital Edition

Chromatography Today - March 2021

March 2021

In This Edition Modern & Practical Applications - Advancing Effective Glycan Analysis - Delivering the Power of Ion Mobility Spectrometry - Mass Spectrometry to the Point of Analysis - The...

View all digital editions

Events

ISCC & GCxGC 2021 - CANCELLED

May 09 2021 Fort Worth, Tx, USA

e-PREP 2021

Jun 06 2021 Virtual event

MEDLAB MIDDLE EAST

Jun 21 2021 Dubai, UAE & Online

ISSS 2021 - POSTPONED

Jun 29 2021 Ljubljana, Slovenia

EuroAnalysis 2021 - cancelled

Aug 22 2021 Nijmegen, Netherlands

View all events