Analysis of mRNA coupled to enhanced green fluorescent protein by RP and IEX

Dec 14 2022

Oligonucleotides are important in genetic testing, research and forensics. For quite some time now, oligonucleotide-based approaches have been developed for different pharmaceutical applications. To monitor the temporal and dimensional spreading of oligonucleotides or proteins, they can be coupled to enhanced green fluorescent protein (EGFP).

Enhanced green fluorescent protein

EGFP has a molecular weight of 26.9 kDa and is a single point mutation of the green fluorescent protein (GFP) which was first derived from jelly fish Aequorea Victoria. EGFP has improved spectral characteristics such as higher stability and a shift of the major extinction from 395 nm to 488 nm while the major emission is kept at 507 nm, which makes EGFP more suitable for existing spectral analyses.

Gold standard: ion pair reversed phase

Ion pair reversed phase liquid chromatography (IP-RP) continues to be the gold standard method for the characterisation of oligonucleotides. Certainly, the electron-rich backbone of oligonucleotides and the typical use of stainless-steel columns and tubing can cause an irreversible adsorption. This occurs due to ionic interactions with the positively charged metal oxide layer of the component’s surfaces.

This effect is even more critical when working at low to neutral pH as metals are more electropositive at these conditions. To overcome these challenges bioinert systems and columns such as the recently introduced YMC-Accura Triart columns can be used. YMC-Accura Triart columns have a bioinert coating on all surfaces, including the frits, to prevent any unwanted ionic interactions.

Bioinert widepore column as ideal choice here

This application note shows the analysis of EGFP mRNA (996 nt). For the analysis of oligonucleotides columns with C18 modifications are commonly used. However, due to its high molecular weight and the accompanied high hydrophobicity a wide pore column with short chains such as C4 is more suitable for this kind of analysis. Excellent peak shapes and recoveries are achieved using a bioinert YMC-Accura Triart Bio C4 column with 300 Å at pH 7 and 80 °C.

Alternative approach: anion exchange chromatography

In addition to RP based methods, ion exchange (IEX) methods can provide an alternative approach. The strong anion exchanger BioPro IEX QF has a quaternary amine residue as the functional group. This non-porous column offers high efficiency, exceptionally high resolution at low operating pressures independent from the analytes’ molecular weight. The application note also shows the IEX separation of EGFP mRNA (996 nt) using a BioPro IEX QF column. Exceptionally sharp peaks are obtained in under 10 minutes applying a salt gradient using sodium chloride and relatively mild temperatures.


Digital Edition

Chromatography Today - Buyers' Guide 2022

October 2023

In This Edition Modern & Practical Applications - Accelerating ADC Development with Mass Spectrometry - Implementing High-Resolution Ion Mobility into Peptide Mapping Workflows Chromatogr...

View all digital editions

Events

AOCS Annual Meeting & Expo

Apr 28 2024 Montreal, Quebec, Canada

SETAC Europe

May 05 2024 Seville, Spain

ChemUK 2024

May 15 2024 Birmingham, UK

MSB 2024

May 19 2024 Brno, Czech Republic

Water Expo Nigeria 2024

May 21 2024 Lagos, Nigeria

View all events