The most common technique used for the analysis of Organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) at trace level is gas chromatography coupled to an electron capture detector (GC-ECD). ECD detection grants excellent sensitivity and good selectivity. However, for very complex matrices interference can become an issue. In recent years, the use of GC coupled to tandem mass spectrometry (GC-MS/MS) has been investigated. The main limitation of these approaches is their applicability exclusively for targets.

Comprehensive two-dimensional gas chromatography (GCxGC) benefits from the coupling of two different separation mechanism in a single analysis. This provides enhanced resolution and peak capacity, leading to superior separation power and much less chance for co-elution.

In a preliminary study JSB investigated the performance of GCxGC with thermal modulation coupled to a QTOF detector for quantification of OCPs and PCBs at low concentrations. The QTOF allows for acquisition in Election Ionisation (EI) and Chemical Ionisation (positive and negative modes available).

JSB concluded that GCxGC with thermal modulation provides higher resolution power than standard GC and allows for easier, detailed separation of complex OCPs and PCBs mixtures. Thanks to the higher peak capacity, co-elution is much less likely even with very dirty matrices. When coupled to MS in scan mode simultaneous identity confirmation for targets and identification of unknowns was allowed. This is not possible with ECD or a triple quadrupole (MS/MS).

The QTOF’s high resolution and mass accuracy provided additional

identification confidence, selectivity and sensitivity. Results obtained for linearity and repeatability show that GCxGC with thermal modulation and QTOF are robust and provide performance suitable for reliable identification and quantification. NCI mode provided good sensitivity for chlorinated compounds such as OCPs and PCBs. The option to switch from EI to CI mode, in combination with the MS/MS capability, granted wide operational flexibility.


Digital Edition

Chromatography Today - Buyers' Guide 2022

December 2021

In This Edition Modern & Practocal Applications - Accelerating ADC Development with Mass Spectrometry - Implementing High-Resolution Ion Mobility into Peptide Mapping Workflows Chromatogr...

View all digital editions

Events

ACS National Meeting & Expo, Spring 2023

Mar 26 2023 Indianapolis, IN, USA

Korea Lab 2023

Apr 18 2023 Kintex, South Korea

Analytica Vietnam

Apr 19 2023 Ho Chi Minh City, Vietnam

SETAC Europe

Apr 30 2023 Dublin, Ireland & Online

AOCS Annual Meeting & Expo

Apr 30 2023 Denver, CO, USA

View all events