• How Does Gas Chromatography Work?   

Bioanalytical

How Does Gas Chromatography Work?   

Jun 26 2014

Gas chromatography (or GC as it is typically called) is a standard type of chromatography used regularly in analytical chemistry. But how does it work? Gas chromatography is the process of separating, identifying and quantifying the various compositional elements of a compound. This is achieved by measuring how each of the different components reacts with being converted from a liquid or solid stationary phase into a mobile gas phase. Each component has a consistent time that it will take to achieve this reaction, and as such, it can be readily and accurately identified 
depending on this reaction time.

Single Column Gas Chromatography

The oldest and simplest form of chromatography simply involves one column and measures one dimension of the sample. The matter to be tested is vaporised into a gas and combined with a specific solvent, whose quantity is known and recorded, and then the final eluate is measured by a detector. 
 
This method of chromatography has several drawbacks. Most notably, it is not effective in determining the presence of substances in trace amounts, and neither can it fully detect all of the components in a compound made up of more than 50 or 60 different ingredients.

Multidimensional Gas Chromatography (MDGC)

A more advanced form of chromatography, MDGC introduces a second or even third column to detect a different dimension of the sample. Normally one of these columns is polar while the other is non-polar. This is done by using a Dean’s Switch, which is remotely-operated and which sends a part of the eluate to the second column. This part is only a fraction of the whole sample – as a result, this process is often referred to as “heart-cutting”, since a portion of the eluate is “cut” from the “heart” of the sample. 

Whilst this technique does improve data production and knowledge of the peak times by using multiple dimensions, it is limited in that only a portion of the sample is transferred to the second column. This problem can be circumvented by the advent of comprehensive gas chromatography. 

Comprehensive Gas Chromatography (GC x GC)

GC x GC eliminates the problem of losing part of the sample to the first detector before it reaches the second column by the introduction of a modulator. This modulator has the job of trapping, identifying and isolating individual components, grouping them together, and then sending them onto the second column. Doing things this way ensures that the entire sample is exposed to both columns and maximum accuracy and precision is achieved in the results. 

The Methods of Gas Chromatography in Practical Application 

One particular application of gas chromatography is the analysis of such substances as oil and petrol. This article: Determination of Biomarkers in Petroleum by Multidimensional Gas Chromatography: Fundamentals, Applications and Future Perspectives, discusses each of these approaches to the process in detail, and how they relate specifically to the topic of petrol study.


Digital Edition

Chromatography Today - Buyers' Guide 2022

October 2023

In This Edition Modern & Practical Applications - Accelerating ADC Development with Mass Spectrometry - Implementing High-Resolution Ion Mobility into Peptide Mapping Workflows Chromatogr...

View all digital editions

Events

analytica 2024

Apr 09 2024 Munich, Germany

Korea Lab 2024

Apr 23 2024 Kintex, South Korea

Korea Chem 2024

Apr 23 2024 Seoul, South Korea

AOCS Annual Meeting & Expo

Apr 28 2024 Montreal, Quebec, Canada

SETAC Europe

May 05 2024 Seville, Spain

View all events