Selective Depletion of Phospholipids in Bioanalysis using HybridSPE-PPT Technology

Solid phase extraction (SPE)

Selective Depletion of Phospholipids in Bioanalysis using HybridSPE-PPT Technology

15 Oct, 2009

Published over 16 years ago. See the latest and most current information on Solid phase extraction (SPE).

Craig Aurand and An Trinh
1 min read
Download

The approach of this study was to evaluate the performance of recently developed sample prep platform HybridSPE(TM) Precipitation(HybridSPE-PPT)for the purpose of matrix removal and analyte recovery from spiked plasma samples. The goal of the study was to demonstrate how the HybridSPE-PPT platform can increase bioanalytical throughput by both decreasing sample preparation time and improving chromatographic analysis and detection relative to traditional protein precipitation methods.

Often the major concern in developing bioanalytical methods is addressing the effect of endogenous biological matrix components on the detection of desired analytes. The impact of matrix effects in bioanalysis has

been well documented [1,2]. In the majority of cases, co-extracted interferences directly affect the quantitation of analytes due to ionization effects induced by the extracted matrix. This extracted matrix can impact the

chromatographic analysis, but more often is a result of chromatographic build up that leads to irregularities. Chromatographic build up of phospholipids is often observed when performing standard protein precipitation

techniques [3,5]. Adequate removal of phospholipids from the analytical column often result in the need for gradient elution under reversed-phase separations resulting in prolonged analysis. Even ballistic conditions

often used with modern UHPLC instruments are inadequate to remove phospholipids that a have accumulated on the column. In most cases gradient elution is not required for resolution of desired analytes, but instead

required only to elute extracted matrix from the analytical column.

Explore Our Other Sites

Labmate Online
Up to half of kidney disease cases remain undiagnosed, Lancet series warns
Explore more Arrow
Envirotech Online
Real-time gas detection integrated into robotic inspections for safer hazard assessment
Explore more Arrow
Pollution Solutions Online
Next-generation reverse osmosis membranes for more efficient and cost-effective seawater desalination
Explore more Arrow
Petro Online
SAF shortfall puts fuel testing and blending control under pressure
Explore more Arrow