• New Column Designed for Increased Sensitivity for Rapid LC/MS Analyses

HPLC, UHPLC

New Column Designed for Increased Sensitivity for Rapid LC/MS Analyses

Jun 22 2015

A new column for liquid chromatography-mass spectrometry (LC/MS) analysis uses a unique capillary design to offer labs with limited samples and complex mixtures a fast and high-resolution solution for the identification of protein samples, facilitating high sensitivity proteomics and biotech applications.

The Thermo Scientific ProSwift C4 RP-5H column incorporates a exceptionally designed, low-pressure C4 monolith with a porous structure, enabling faster low-flow separations without sacrificing resolution compared with typical porous bead based media. Offering a wide range of operational flow rates, alternative selectivity and low carryover, the ProSwift C4 RP-5H is suited for rapid LC/MS analysis of protein samples.

The new column’s porous copolymer gives the flow channels higher permeability in the stationary phase than particulate columns, resulting in increased separation efficiency. Due to this structure, smaller i.d. columns of 50 μm can be used for analyses, increasing sensitivity.

“The new ProSwift C4 RP-5H column is a great addition to our capillary portfolio as it solves the issues of carryover that can be experienced when analysing hydrophobic protein samples” said David Sarracino, manager of biomarker workflows at Thermo Fisher’s Biomarkers Research Initiatives in Mass Spectrometry (BRIMS) Centre. “The ProSwift C4 RP-5H column is available in a range of column formats for nano, capillary and micro flow chromatography, offering excellent resolution for large, hydrophobic intact proteins across biopharma and research proteomics. This enables flow optimisation for increased MS sensitivity as well as rapid separation of monoclonal antibody and complex protein samples.”

The ProSwift C4 RP-5H column will be exhibited for the first time at the 42nd International HPLC Conference in Geneva, Switzerland, Booth 14, June 21–25.

The new monolith uses a butyl (C4) methacrylate co-polymer that is less hydrophobic than PS-DVB columns, meaning there is less column fouling. This is important for MS users where sensitivity is higher compared to UV and carryover can cause interference.

More information on the ProSwift C4 RP-5H columns, can be found by clicking here.


Digital Edition

Chromatography Today - Buyers' Guide 2022

October 2023

In This Edition Modern & Practical Applications - Accelerating ADC Development with Mass Spectrometry - Implementing High-Resolution Ion Mobility into Peptide Mapping Workflows Chromatogr...

View all digital editions

Events

AOCS Annual Meeting & Expo

Apr 28 2024 Montreal, Quebec, Canada

SETAC Europe

May 05 2024 Seville, Spain

ChemUK 2024

May 15 2024 Birmingham, UK

MSB 2024

May 19 2024 Brno, Czech Republic

Water Expo Nigeria 2024

May 21 2024 Lagos, Nigeria

View all events