New Method for Low Level Detection of Volatile Nitrosamines in Tobacco  

Thermo Fisher Scientific announce a new comprehensive method that uses triple quadrupole GC-MS/MS to achieve lower levels of detection of volatile nitrosamines (VNA) in tobacco. The new method allows environmental laboratories, tobacco companies and government agencies to efficiently separate VNAs while lowering detection limits, increasing specificity and enabling the analysis of many other contaminants in tobacco, including pesticides. The new method is detailed in an application note entitled “Lower Detection Limits of Volatile Nitrosamines in Tobacco by Triple Quadrupole GC-MS/MS,” available to download at www.thermoscientific.com/vna.

Volatile nitrosamines are a class of compounds that can form in tobacco smoke, as well as during the curing and processing of tobacco. These compounds have been proven to have adverse effects on human health; and two of the VNAs found in tobacco, N-nitrosodiethylamine (NDEA) and N-nitrosodimethylamine (NDMA), are classed as known human carcinogens by regulatory authorities. As a result, these compounds must be thoroughly monitored in order to safeguard human health and comply with increasingly stringent regulations.

The new Thermo Fisher method is a powerful alternative to other traditionally used techniques. By coupling a gas chromatograph to a triple quadrupole mass spectrometer, the new method makes detection limits of 1ng/mL achievable, enabling users to satisfy the increasingly lower detection limits required by governments and regulatory bodies. The method also increases contaminant specificity within a classification and allows many other organic contaminants and chemicals in tobacco to be analyzed simultaneously, including pesticides.

The new method includes GC-MS/MS analysis on the Thermo Scientific TSQ Quantum XLS triple quadrupole GC-MS/MS system using timed selected reaction monitoring (t-SRM). This unique feature enables easy method set-up and allows users to run samples while the instrument automatically determines the optimal time for SRM parameters.

For more information visit www.thermoscientific.com/gc.
 

top of page Filed under: GC, MDGC, GC-MS

Reader Comments (Total 0 comments)

Post a comment

Do you like or dislike what you have read? Why not post a comment to tell others / the manufacturer and our Editor what you think. To leave comments please complete the form below. Providing the content is approved, your comment will be on screen in less than 24 hours. Leaving comments on product information and articles can assist with future editorial and article content. Post questions, thoughts or simply whether you like the content.