3-Dimensional Retention Modelling of Gradient Time, Ternary Solvent-Strength and Temperature of the Reversed-phase Gradient Liquid Chromatography of a Complex Mixture of 22 Basic and Neutral Analytes using DryLab® 2010 - Melvin R Euerbya, Gesa Sch

HPLC, UHPLC

3-Dimensional Retention Modelling of Gradient Time, Ternary Solvent-Strength and Temperature of the Reversed-phase Gradient Liquid Chromatography of a Complex Mixture of 22 Basic and Neutral Analytes using DryLab® 2010 - Melvin R Euerbya, Gesa Sch

17 Dec, 2010

Published over 15 years ago. See the latest and most current information on HPLC, UHPLC.

Melvin R Euerbya, Gesa Schada, Hans-Jürgen Riegerb, Imre Molnárb
1 min read
Download

The present paper describes a multi-factorial optimization of three critical HPLC method parameters, i.e. gradient time (tG), temperature (T), and ternary composition (B1:B2) based on twelve experiments for the separation of twenty-two pharmaceutically relevant analytes. Examining the effect of these experimental variables on critical resolution and selectivity was carried out in such a way as to systematically vary all three factors simultaneously. The basic element is a gradient time–temperature (tG –T) plane, which is repeated at three different ternary compositions of eluent B between methanol and acetonitrile. The so-defined volume enables the investigation of the critical resolution for a part of the Design Space of a given sample. Multi-dimensional robust regions were successfully defined, graphically depicted and verified. The paper highlights the applicability of this approach for the rapid development of high quality robust LC methodologies.

Introduction

The use of Quality by Design (QbD) and Design Space (DS) principles [1] is becoming increasingly popular within the pharmaceutical environment. Regulatory authorities, including the Federal Drug Administration (FDA) and International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH), are actively promoting and demanding the application of these risk-based approaches to drug development in order to ensure a systematic approach in developing analytical methods.

Explore Our Other Sites

Labmate Online
Enhanced recirculating chiller range
Explore more Arrow
Envirotech Online
Rack-mountable FTIR gas analyser for integrated multi-gas analysis in fixed measurement systems
Explore more Arrow
Pollution Solutions Online
New all-in-one fish silage system for aquaculture and fish processing industries
Explore more Arrow
Petro Online
Free webinar: enhancing accuracy and efficiency in renewable fuel laboratory testing
Explore more Arrow